Sample FitCheck Report Table

Below is a sample table which is provided with our FITCHECK report including comments/improvements
with further instruction of the employee and our recommendations.

Date

Name

Department

HPD/Model

# of disposable plugs worn/day

NRR

PAR

Comments

12/12/2006

A. A.

Generation

E.A.R. Classics

3

30

14.4

Employee ear canals are too small for Classics. Employee

Center Frequency in Hz

 

able to achieve adequate self fit with EZ Fit

250 Hz

 

500 Hz

 

1000 Hz

 

2000 Hz

 

4000 Hz

 

8.9

 

8.1

 

12.6

 

31.1

 

25.9

 

E-Z Fit Retest - PAR # 24.4,

19.2

18.9

24.3

40.7

46

26

24.4

Improvement of 10 dB

Date

Name

Department

HPD/Model

# of disposable plugs worn/day

NRR

PAR

Comments

12/12/2006

B. B.

Maintenance

Taperfit 2 Reg.

8

32

10.2

Canals are too large for earplugs used. Recommended HPD's:

Center Frequency in Hz

 

Grande or Taper Fit 2 Large size. After reinstruction employee was able to properly self fit

250 Hz

 

500 Hz

 

1000 Hz

 

2000 Hz

 

4000 Hz

 

5.4

 

2.4

 

11.0

 

30.4

 

39.3

 

TF2 Large Retest - PAR of 31 dB

25

28.8

26.4

41.9

44.6

29

31.1

Improvement of 21 dB

Date

Name

Department

HPD/Model

# of disposable plugs worn/day

NRR

PAR

Comments

12/12/2006

C. C.

Maintenance

Spark Plugs

5

30

33.2

Excellent fit!

Center Frequency in Hz

 

 

250 Hz

 

500 Hz

 

1000 Hz

 

2000 Hz

 

4000 Hz

 

 

37.6

 

43.3

 

45.1

 

43.0

 

44.1

 

 

Date

Name

Department

HPD/Model

# of disposable plugs worn/day

NRR

PAR

Comments

12/12/2006

D.D.

Control Room

E.A.R. Classics

3

30

21.2

Note NRR could improve however

 

employee has significant hearing loss and is rarely exposed to noise

 

 

 

 

 

And when he is, it's a brief walk thru @ 88dBA SPL.

17.1

 

17.4

 

17.0

 

35.8

 

34.8